5 resultados para single step PCR

em Repositório Institucional da Universidade de Aveiro - Portugal


Relevância:

80.00% 80.00%

Publicador:

Resumo:

According to the World Health Organization, around 8.2 million people die each year with cancer. Most patients do not perform routine diagnoses and the symptoms, in most situations, occur when the patient is already at an advanced stage of the disease, consequently resulting in a high cancer mortality. Currently, prostate cancer is the second leading cause of death among males worldwide. In Portugal, this is the most diagnosed type of cancer and the third that causes more deaths. Taking into account that there is no cure for advanced stages of prostate cancer, the main strategy comprises an early diagnosis to increase the successful rate of the treatment. The prostate specific antigen (PSA) is an important biomarker of prostate cancer that can be detected in biological fluids, including blood, urine and semen. However, the commercial kits available are addressed for blood samples and the commonly used analytical methods for their detection and quantification requires specialized staff, specific equipment and extensive sample processing, resulting in an expensive process. Thus, the aim of this MSc thesis consisted on the development of a simple, efficient and less expensive method for the extraction and concentration of PSA from urine samples using aqueous biphasic systems (ABS) composed of ionic liquids. Initially, the phase diagrams of a set of aqueous biphasic systems composed of an organic salt and ionic liquids were determined. Then, their ability to extract PSA was ascertained. The obtained results reveal that in the tested systems the prostate specific antigen is completely extracted to the ionic-liquid-rich phase in a single step. Subsequently, the applicability of the investigated ABS for the concentration of PSA was addressed, either from aqueous solutions or urine samples. The low concentration of this biomarker in urine (clinically significant below 150 ng/mL) usually hinders its detection by conventional analytical techniques. The obtained results showed that it is possible to extract and concentrate PSA, up to 250 times in a single-step, so that it can be identified and quantified using less expensive techniques.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

According to the World Health Organization, around 8.2 million people die each year with cancer. Most patients do not perform routine diagnoses and the symptoms, in most situations, occur when the patient is already at an advanced stage of the disease, consequently resulting in a high cancer mortality. Currently, prostate cancer is the second leading cause of death among males worldwide. In Portugal, this is the most diagnosed type of cancer and the third that causes more deaths. Taking into account that there is no cure for advanced stages of prostate cancer, the main strategy comprises an early diagnosis to increase the successful rate of the treatment. The prostate specific antigen (PSA) is an important biomarker of prostate cancer that can be detected in biological fluids, including blood, urine and semen. However, the commercial kits available are addressed for blood samples and the commonly used analytical methods for their detection and quantification requires specialized staff, specific equipment and extensive sample processing, resulting in an expensive process. Thus, the aim of this MSc thesis consisted on the development of a simple, efficient and less expensive method for the extraction and concentration of PSA from urine samples using aqueous biphasic systems (ABS) composed of ionic liquids. Initially, the phase diagrams of a set of aqueous biphasic systems composed of an organic salt and ionic liquids were determined. Then, their ability to extract PSA was ascertained. The obtained results reveal that in the tested systems the prostate specific antigen is completely extracted to the ionic-liquid-rich phase in a single step. Subsequently, the applicability of the investigated ABS for the concentration of PSA was addressed, either from aqueous solutions or urine samples. The low concentration of this biomarker in urine (clinically significant below 150 ng/mL) usually hinders its detection by conventional analytical techniques. The obtained results showed that it is possible to extract and concentrate PSA, up to 250 times in a single-step, so that it can be identified and quantified using less expensive techniques.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main objective of the present work is the study of a profitable process not only in the extraction and selective separation of lycopene and β-carotene, two compounds present in tomato, but also in its potential application to food industry wastes. This is one of the industries that produce larger amounts of wastes, which are rich in high value biomolecules with great economic interest. However, the conventional methods used to extract this kind of compounds are expensive which limits their application at large scale. Lycopene and βcarotene are carotenoids with high commercial value, known for their antioxidant activity and benefits to human health. Their biggest source is tomato, one of the world’s most consumed fruits, reason for which large quantities of waste is produced. This work focuses on the study of diverse solvents with a high potential to extract carotenoids from tomato, as well as the search for more environmentally benign solvents than those currently used to extract lycopene and β-carotene from biomass. Additionally, special attention was paid to the creation of a continuous process that would allow the fractionation of the compounds for further purification. Thus, the present work started with the extraction of both carotenoids using a wide range of solvents, namely, organic solvents, conventional salts, ionic liquids, polymers and surfactants. In this stage, each solvent was evaluated in what regards their capacity of extraction as well as their penetration ability in biomass. The results collected showed that an adequate selection of the solvents may lead to the complete extraction of both carotenoids in one single step, particularly acetone and tetrahydrofuran were the most effective ones. However, the general low penetration capacity of salts, ionic liquids, polymers and surfactants makes these solvents ineffective in the solid-liquid extraction process. As the organic solvents showed the highest capacity to extract lycopene and βcarotene, in particular tetrahydrofuran and acetone, the latter solvent used in the development process of fractionation, using to this by strategic use of solvents. This step was only successfully developed through the manipulation of the solubility of each compound in ethanol and n-hexane. The results confirmed the possibility of fractionating the target compounds using the correct addition order of the solvents. Approximately, 39 % of the β-carotene was dissolved in ethanol and about 64 % of lycopene was dissolved in n-hexane, thus indicating their separation for two different solvents which shows the selective character of the developed process without any prior stage optimization. This study revealed that the use of organic solvents leads to selective extraction of lycopene and β-carotene, allowing diminishing the numerous stages involved in conventional methods. At the end, it was possible to idealize a sustainable and of high industrial relevance integrated process, nevertheless existing the need for additional optimization studies in the future.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main objective of the present thesis consists on the development of an analytical preconcentration technology for the concomitant extraction and concentration of human pollution tracers from wastewater streams. Due to the outstanding tunable properties of ionic liquids (ILs), aqueous biphasic systems (ABS) composed of ILs can provide higher and more selective extraction efficiencies for a wide range of compounds, being thus a promising alternative to the volatile and hazardous organic solvents (VOCs) typically used. For that purpose, IL-based ABS were employed and adequately characterized as an one-step extraction and concentration technique. The applicability of IL-based ABS was verified by their potential to completely extract and concentrate two representative pharmaceutical pollution tracers, namely caffeine (CAF) and carbamazepine (CBZ), from wastewaters. The low concentration of these persistent pollutants (usually found in μg·dm-3 and ng·dm-3 levels, respectively) by conventional analytical equipment does not permit a proper detection and quantification without a previous concentration step. Preconcentration methods commonly applied are costly, timeconsuming, with irregular recoveries and make use of VOCs. In this work, the ABS composed of the IL tetrabutylammonium chloride ([N4444]Cl) and the salt potassium citrate (K3[C6H5O7]) was investigated while demonstrating to be able to completely extract and concentrate CAF and CBZ, in a single-step, overcoming thus the detection limit of the applied analytical equipment. Finally, the hydrotropic effect responsible for the ability of IL-based ABS to extract and concentrate a wide variety of compounds was also investigated. It was shown that the IL rules the hydrotropic mechanism in the solubility of CAF in aqueous solutions, with an increase in solubility up to 4-fold. Moreover, the proper selection of the IL enables the design of the system that leads to a more enhanced solubility of a given solute in the IL-rich phase, while allowing a better extraction and concentration. IL-based ABS are a promising and more versatile technique, and are straightforwardly envisaged as selective extraction and concentration routes of target micropollutants from wastewater matrices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Permanece por esclarecer como a via de sinalização do cAMP modula a exocitose regulada. Os principais objetivos deste trabalho foram: i) avaliar o efeito do cAMP nos eventos exocitóticos, nas propriedades dos poros de fusão e na secreção hormonal; ii) perceber o impacto da sinalização por cAMP-HCN na exocitose e nas propriedades do poro de fusão; e iii) estudar as propriedades do poro de fusão na presença de um agente neurotóxico comum, como o alumínio. Lactotrofos, isolados a partir da hipófise anterior de ratos Wistar machos, foram usados como modelo celular. Os eventos unitários de fusão exocitótica e a prolactina (PRL) libertada foram avaliados, respetivamente, em ensaios eletrofisiológicos efectuados segundo a técnica de contacto hermético no modo sobre a célula aderida à pipeta porta-elétrodo e com recurso a métodos imunológicos de deteção. Os níveis intracelulares de cAMP foram aumentados por 3-isobutil-1-metilxantina (IMBX), forscolina e N6,2'-O-dibutiril adenosina- 3',5'-monofosfato cíclico (dbcAMP). A expressão dos canais HCN foi determinada por Western-blot, qRT-PCR e imunocitoquímica em combinação com microscopia confocal. Culturas primárias de lactotrofos foram também transfetadas com DNA plasmídico que codifica HCN2 juntamente com a proteína-verde-fluorescente e um agente farmacológico foi usado para avaliar o efeito de cAMP-HCN na exocitose. Observou-se que os lactotrofos responderam à forscolina e ao dbcAMP libertando PRL de um modo bifásico e dependente da concentração, uma vez que a secreção aumentou e diminuiu, respectivamente, na gama de baixas e altas concentrações. Os compostos que elevaram os níveis de cAMP aumentaram os eventos transientes e impediram a fusão completa. Além disso, o dbcAMP promoveu o aparecimento de eventos exocitóticos transientes de elevada periodicidade, cujos poros de fusão, de maior diâmetro, se mativeram abertos durante mais tempo. A expressão das quatro isoformas de HCN foi confirmada nos lactotrofos ao nível do mRNA e, tal como no coração, rim e hipófise, o mais abundante codifica a isoforma HCN2. Nos lactotrofos com sobre-expressão desta isoforma, o dbcAMP não só aumentou a frequência dos eventos transientes e a condutância dos poros, mas também a frequência dos eventos de fusão completa. Enquanto o bloqueador dos canais HCN, ZD7288, reduziu a frequência dos eventos transientes e de fusão completa desencadeados por dbcAMP e diminuiu o diâmetro dos poros de fusão. A simultânea diminuição da libertação de PRL, da frequência dos eventos transientes e do diâmetro dos poros de fusão representaram as principais alterações observados após pré-tratamento dos lactotrofos com concentração micromolar de alumínio. Em conclusão, os resultados demonstram que elevados níveis de cAMP reduzem a secreção de PRL devido à estabilização dos poros de fusão no estado de maior abertura. Além disso, a via de sinalização cAMP-HCN afecta a actividade exocitótica e modifica as propriedades dos poros de fusão, que parecem ser igualmente importantes na citotoxicidade induzida por alumínio.